Dry Transformer and Oil Immersed Transformer Manufacturer

S22 Oil Immersed Transformer

OIL IMMERSED TRANSFORMERS

S22 Oil Immersed Transformer

The S22 oil-immersed transformers are meticulously crafted to excel in efficiency, with minimal load losses ensuring maximum energy transfer and reduced operational costs. Additionally, the reduction in no-load current enhances system stability and minimizes power consumption during idle periods, further optimizing energy efficiency and performance.

Introduction of S22 Oil Immersed Transformer

The S22 oil-immersed transformer embodies several key characteristics that define its quality and performance:

Efficiency: The S22 transformer is engineered to minimize energy losses, including load losses and no-load losses, ensuring efficient energy transfer and optimal performance.

Reliability: With a robust design and high-quality materials, the S22 transformer offers exceptional reliability, reducing downtime and ensuring long-term operation.

Cooling System: The S22 transformer features an effective cooling system, such as oil circulation or natural convection, to maintain ideal operating temperatures and prevent overheating.

Insulation: The S22 transformer is equipped with reliable insulation between windings and core to ensure safety, prevent electrical faults, and support efficient energy transfer.

Voltage Regulation: This transformer excels in voltage regulation, maintaining stable output voltages across varying load conditions.

Environmental Considerations: The S22 transformer prioritizes eco-friendly practices by using biodegradable insulating oils and materials with minimal environmental impact.

Maintenance: Designed for easy maintenance, the S22 transformer allows for straightforward inspection and servicing, contributing to its longevity and reliability.

Safety Features: Equipped with safety features such as overcurrent protection, temperature monitoring, and fault detection systems, the S22 transformer ensures safety and reliability in operation.

Technical Specification of S22 Oil Immersed Transformer

Capacity
(KVA)
No-load Loss
(W)
Load LossImpedance Voltage
(%)
No-load Current
(%)
Vector GroupExtend Connection
Dyn11/Yzn11Yyno
30654554304.00.5Yyn0 OR Dyn11±2*2.5%
Or±5%
50806556250.5
63907857450.5
801059459000.45
100120114010800.45
125135136012950.45
160160166515850.4
200190197018700.4
250230230021950.4
315270276026300.35
400330325030950.35
500385390037100.3
63046044604.50.25
80056054000.18
100066574150.17
125078086400.17
1600940104400.16
20001085131805.00.16
25001280133600.16

Drawing of Oil Immersed Transformer

Please enable JavaScript in your browser to complete this form.

Get in Touch

S20 Oil Immersed Transformer

OIL IMMERSED TRANSFORMERS

S20 Oil Immersed Transformer

S20 oil-immersed transformer is a type of electrical transformer where the core and windings are immersed in an insulating oil. This oil serves as a coolant and insulating medium to dissipate heat generated during transformer operation and to provide insulation between windings and core.

Introduction of S20 Oil Immersed Transformer

S20 oil-immersed transformers stand out as essential components in power distribution systems. 

With their core and windings submerged in insulating oil, play a crucial role in ensuring efficient energy transfer and reliable power supply.

One key aspect that sets apart high-quality oil-immersed transformers is the management of load losses. Load loss, the power dissipated as heat when the transformer is supplying a load, holds significant importance in transformer performance and energy efficiency.

 

Lower load losses translate to higher energy efficiency, enabling the transformer to operate more effectively while minimizing energy wastage. This efficiency not only leads to cost savings for users but also contributes to a greener environment by reducing overall energy consumption.

 

By prioritizing the reduction of load losses in oil-immersed transformers, we aim to deliver products that excel in performance, reliability, and energy efficiency. S20 transformers not only meet the demands of modern power distribution systems but also pave the way for sustainable energy solutions that benefit both users and the environment.

Technical Specification of S20 Oil Immersed Transformer

Capacity
(KVA)
No-load Loss
(W)
Load LossImpedance Voltage
(%)
No-load Current
(%)
Vector GroupExtend Connection
Dyn11/Yzn11Yyno
30705054804.00.50Yyn0 OR Dyn11±2*2.5%
Or±5%
50907306950.50
631008708300.50
80115105010000.45
100135126512000.45
125150151014400.45
160180185017600.40
200215218520800.40
250260256024400.40
315305306529200.35
400370361534400.35
500430433041200.30
63051049604.50.25
80063060000.18
100074582400.17
125087096000.17
16001050116000.16
20001225146405.00.16
25001440148400.16

Drawing of Oil Immersed Transformer

Please enable JavaScript in your browser to complete this form.

Get in Touch

S13 Oil Immersed Transformer

OIL IMMERSED TRANSFORMERS

S13 Oil Immersed Transformer

S13 oil-immersed transformer is crafted to set a new standard in efficiency and reliability for electrical systems. Standout among its features is the remarkable reduction in load losses and minimal no-load current, ensuring optimal performance and cost-effectiveness.

Introduction of S13 Oil Immersed Transformer

Crafted with precision and innovation, the S13 transformer is designed to minimize energy wastage by significantly lowering load losses. This translates to enhanced energy efficiency, cost savings, and a greener footprint for your power distribution network.

Furthermore, the S13 transformer’s advanced design leads to a decrease in no-load current, promoting efficient operation and minimal power consumption during idle periods. This not only enhances system efficiency but also ensures a stable and reliable power supply for your operations.

Superior performance, energy efficiency, and operational cost savings with our S13 oil-immersed transformer. Elevate your power distribution infrastructure to new levels of efficiency and reliability with our innovative transformer solution.

Oil-immersed transformers can be widely used in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises, drilling platforms, and oil production platforms. They are especially suitable for use in places with high fire protection requirements and harsh environments such as flammable and explosive materials. They can also be used for power and lighting in residential areas, commercial streets, industrial and mining enterprises, and rural areas.

Technical Specification of S13 Oil Immersed Transformer

Capacity
(KVA)
No-load Loss
(W)
Load LossImpedance Voltage
(%)
No-load Current
(%)
Vector GroupExtend Connection
Dyn11/Yzn11Yyno
30806306004.00.63Yyn0 OR Dyn11±2*2.5%
Or±5%
501009108700.6
63110109010400.57
80130131012500.54
100150158015000.48
125170189018000.45
160200231022000.42
200240273026000.39
250290320030500.36
315340383036500.38
400410452043000.3
500480541051500.3
63057062004.50.27
80070075000.24
1000830103000.21
1250970120000.18
16001170145000.18
20001360183005.0
2500160021200
S13-M.RL Three-dimensional Wound Core Power Transformer
meodelRated Capacity (KVA)Connection Group SymbolVoltage CombinationNo-load Loss R(W)Load Loss R(W)No-load Current (%)Impedance Voltage(%)
High Voltage (KV)Tapping Range of High VoltageLow Voltage (KV)
S13-M.RL30Dyn11 Yzml1 Yyno6 6.3 10 10.5 11±5% ±2×2.5%0.4806000.34
S13-M.RL501008700.24
S13-M.RL6311010400.23
S13-M.RL8013012500.22
S13-M.RL10015015000.21
S13-M.RL12517018000.2
S13-M.RL16020022000.19
S13-M.RL20024026000.18
S13-M.RL25029030500.17
S13-M.RL31534036500.16
S13-M.RL40041043000.16
S13-M.RL50048051500.16
S13-M.RL630YynO or Dyn1157062000.154.5
S13-M.RL80070075000.15
S13-M.RL1000830103000.14
S13-M.RL1250970120000.13
S13-M.RL16001170145000.12
S13-M.RL20001360145300.12
S13-M.RL25001500172700.11

Drawing of Oil Immersed Transformer

Please enable JavaScript in your browser to complete this form.

Get in Touch

S11 Oil Immersed Transformer

OIL IMMERSED TRANSFORMERS

S11 Oil Immersed Transformer

The S11 series oil-immersed transformer is to revolutionize power distribution systems. This series boasts advanced features such as enhanced energy efficiency, reduced losses, and improved performance. The S11 transformers are meticulously crafted to deliver superior reliability, optimal energy transfer, and cost-effectiveness. With a focus on sustainability, these transformers are built with eco-friendly materials and innovative technologies to ensure minimal environmental impact.

Introduction of S11 Oil Immersed Transformer

S11 series oil immersed transformer offering the choice between the Yyn0 or Dyn11 vector group configurations across a wide power range from 30 kVA to 2500 kVA. These transformers are engineered to deliver exceptional performance, efficiency, and reliability in diverse industrial and commercial settings.

The Yyn0 vector group configuration provides a specific phase shift angle, ensuring precise voltage regulation and stability in power distribution networks. On the other hand, the Dyn11 configuration offers an alternative phase shift angle, catering to varying operational requirements with flexibility and adaptability.

One of the key advantages of our transformers lies in their superior energy efficiency, reducing power losses and operational costs over the long term. With advanced design features and high-quality materials, these transformers are built to withstand demanding operating conditions and deliver consistent performance.

Oil-immersed transformers can be widely used in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises, drilling platforms, and oil production platforms. They are especially suitable for use in places with high fire protection requirements and harsh environments such as flammable and explosive materials. They can also be used for power and lighting in residential areas, commercial streets, industrial and mining enterprises, and rural areas.

Technical Specification of S11 Oil Immersed Transformer

Capacity
(KVA)
No-load Loss
(W)
Load LossImpedance Voltage
(%)
No-load Current
(%)
Vector GroupExtend Connection
Dyn11/Yzn11Yyno
301006006304.02.1Yyn0 OR Dyn11±2*2.5%
Or±5%
501308709102
63150109010401.9
80180131012501.8
100200158015001.6
125240189018001.5
160280231022001.4
200340273026001.3
250400320030501.2
315480383036501.1
400570452043001.0
500680541051501
63081062004.50.9
80098075000.8
10001150103000.7
12501360120000.6
16001640145000.6
20001940183005.0
2500229021200
S11 35kv Three-phase Dual-winding No-load Voltage Regulation Transformer spec
Rated Capacity (KVA)Voltage CombinationConnection Group SymbolNo-load Loss (W)Load Loss (W)No-load Current (%)Impedance Voltage (%)L*W*H(mm)Active parts Weight (kg) * Oil Weight (kg)Total Weight (kg)
High Voltage (KV)Tapping Range of High VoltageLow Voltage (KV)
63035±2×2.5% 士5%3.15 6.3 10.5Ydl183078600.656.52400*1700*2212210*9003250
80098094000.652500*1850*2392350*10303500
10001150115000.652700*1950*2512490*11803860
12501400139000.552900*2050*2632600*13504350
16001690166000.453050*2130*2752810*15804855
20002170183000.453105*2195*2802800*18005300
25002560196000.453150*2535*2983525*20607665
315035-38.5±2×2.5% 土5%3.15 6.3 10.53040230000.4573920*2725*2843950*22058565
40003610273000.453310*2915*3074825*256010115
50004320313000.453480*3020*3145700*263511305
63005240350000.4583590*2905*3217120*324013510
800035-38.5±2×2.5%3.15 3.3 6.3 6.6 10.5Ynd117200384000.354070*3050*3598875*384016690
100008700453000.354106*2795*36510305*360017690
125001000538000.34570*3010*38412830*431020990
160001210658000.35235*3295*46116010*665027660
200001440795000.35360*3415*46618820*760032170
250001700940000.25105830*3810*48622360*980042600
3150020201120000.256290*4290*52625110*1201049960
S11 35kv No-load Voltage Regulation Transformer Spec
Rated Capacity (KVA)Voltage CombinationNo-load Loss (W)Load Loss (W)Impedance Voltage(%)No-load Current (%)L*W*H(mm)Active parts Weight (kg) Oil Weight (kg)Total Weight (kg)
High Voltage (KV)Tapping Range of High VoltageLow Voltage (KV)
5035 38.5±5% ±2×2.5%0.41601200/11406.51.31195*935*1825300*330860
1002302010/19101.11200*995*1935470*3831130
1252702370/22601.11235*940*1955550*4651335
1602802820/268011285*895*1950580*4851475
2003403320/316011310*1150*1985680*5951755
2504003950/37600.951450*1090*2010860*6502000
3154804750/45300.951930*1065*2320980*7652290
4005805740/54700.851850*1165*20151170*8852725
5006806910/65800.852045*1205*24151340*9603090
63083078600.652085*1240*25151550*8953810
80098094000.652305*1615*26851990*10304510
10001150115000.652545*1540*25902415*14755055
12501400139000.62495*2010*26752480*14055290
16001690166000.62680*2100*27702600*14905450
20001990197000.552790*2180*28602720*15905600
25002360232000.552900*2290*29802830*17205760

Drawing of Oil Immersed Transformer

Please enable JavaScript in your browser to complete this form.

Get in Touch

News 1

News

oil-immersed power transformer

Depending on mature technologies, we made a lot of improvements on the basis of traditional structure:

Spiral winding with longitudinal oil duct that enjoys good inner heat dissipation;

Effective support at winding end surface that further improve the short-circuit resistant capacity of winding;

Adoption of new hoisting structure and body positioning structure that guarantee safety in long-distance transport and in service;

More unique and reliable structure for your option;

Adoption of transformers with more excellent performance  to improve the technical content.

Depending on mature technologies, we made a lot of improvements on the basis of traditional structure:

Spiral winding with longitudinal oil duct that enjoys good inner heat dissipation;

Effective support at winding end surface that further improve the short-circuit resistant capacity of winding;

Adoption of new hoisting structure and body positioning structure that guarantee safety in long-distance transport and in service;

More unique and reliable structure for your option;

Adoption of transformers with more excellent performance  to improve the technical content.

S9 Oil Immersed Transformer

OIL IMMERSED TRANSFORMERS

S9 Oil Immersed Transformer

The S9 series transformer is designed to improve product features, quality, and reliability by using new components, materials, and structures. It enhances electrical strength, mechanical performance, and heat dissipation. With a corrugated oil tank and fully sealed structure, it isolates transformer oil from air, extending its lifespan and reducing maintenance needs.

Introduction of S9 Oil Immersed Transformer

Introducing our S9 series oil-immersed transformers, ranging from 50 kVA to 2500 kVA in rated power. These transformers are designed with a focus on enhancing product features, quality, and reliability. The S9 series incorporates new components, materials, and structures to improve electrical strength, mechanical performance, and heat dissipation capabilities. With options for Vector Group configurations of Yyn0 or Dyn11, these transformers provide efficient and reliable power distribution solutions for various industrial and commercial applications.

Oil-immersed transformers can be widely used in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises, drilling platforms, and oil production platforms. They are especially suitable for use in places with high fire protection requirements and harsh environments such as flammable and explosive materials. They can also be used for power and lighting in residential areas, commercial streets, industrial and mining enterprises, and rural areas.

Technical Specification of S9 Oil Immersed Transformer

HV:11/10.5/10/6.6/6.3/6 LV: 0.4/0.38
Capacity
(KVA)
No-load Loss
(W)
Load LossImpedance Voltage
(%)
No-load Current
(%)
Vector GroupExtend Connection
Dyn11/Yzn11Yyno
301306006304.02.1Yyn0 OR Dyn11±2*2.5%
Or±5%
501708709102
63200109010401.9
80250131012501.8
100290158015001.6
125340189018001.5
160400231022001.4
200480273026001.3
250560320030501.2
315670383036501.1
400800452043001.0
500960541051501
630120062004.50.9
800140075000.8
10001700103000.7
12501950120000.6
16002400145000.6
20002840183005.0
2500335021200

Drawing of Oil Immersed Transformer

Please enable JavaScript in your browser to complete this form.

Get in Touch